Subsecond pore‐scale displacement processes and relaxation dynamics in multiphase flow
2014
With recent advances at X‐ray microcomputed tomography (μCT) synchrotron beam lines, it is now possible to study pore‐scale flow in porous rock under dynamic flow conditions. The collection of four‐dimensional data allows for the direct 3‐D visualization of fluid‐fluid displacement in porous rock as a function of time. However, even state‐of‐the‐art fast‐μCT scans require between one and a few seconds to complete and the much faster fluid movement occurring during that time interval is manifested as imaging artifacts in the reconstructed 3‐D volume. We present an approach to analyze the 2‐D radiograph data collected during fast‐μCT to study the pore‐scale displacement dynamics on the time s…
Quantitation of Microcomputed Tomography-Imaged Ocular Microvasculature
2010
To quantitatively assess microvascular dimensions in the eyes of neonatal wild-type and VEGF(120)-tg mice, using a novel combination of techniques which permit three-dimensional (3D) image reconstruction.A novel combination of techniques was developed for the accurate 3D imaging of the microvasculature and demonstrated on the hyaloid vasculature of the neonatal mouse eye. Vascular corrosion casting is used to create a stable replica of the vascular network and X-ray microcomputed tomography (muCT) to obtain the 3D images. In-house computer-aided image analysis techniques were then used to perform a quantitative morphological analysis of the images.With the use of these methods, differences …
Effective elastic properties of biocomposites using 3D computational homogenization and X-ray microcomputed tomography
2021
A 3D computational homogenization method based on X-ray microcomputed tomography (μCT) was proposed and implemented to investigate how the fiber weight fraction, orthotropy and orientation distribution affect the effective elastic properties of regenerated cellulose fiber-polylactic acid (PLA) biocomposites. Three-dimensional microstructures reconstructed by means of the X-ray μCT were used as the representative volume elements (RVEs) and incorporated into the finite element solver within the computational homogenization framework. The present method used Euclidean bipartite matching technique so as to eliminate the generation of artificial periodic boundaries and use the in-situ solution d…
Prospective Validation of Facial Nerve Monitoring to Prevent Nerve Damage During Robotic Drilling
2019
Facial nerve damage has a detrimental effect on a patient's life, therefore safety mechanisms to ensure its preservation are essential during lateral skull base surgery. During robotic cochlear implantation a trajectory passing the facial nerve at <0.5 mm is needed. Recently a stimulation probe and nerve monitoring approach were developed and introduced clinically, however for patient safety no trajectory was drilled closer than 0.4 mm. Here we assess the performance of the nerve monitoring system at closer distances. In a sheep model eight trajectories were drilled to test the setup followed by 12 trajectories during which the ENT surgeon relied solely on the nerve monitoring system and…